ZKSJ Full Series Water Pump Selection Table

2026-10-13 15:55:21 admin

Note : Parameters are for reference only. Please refer to the official product page for the latest data. 

Units : Vdc , A , m , L/H , L/min , W

SeriesModelVoltage (Vdc)Max Load Current (A)Max Head (m)Max FlowMax Power (W)
DC30DC30 Series4.5–120.35--0.5–4.2
DC40DC40-1220120.452.0350 L/H5.40
DC40DC40-1230120.703.0400 L/H8.40
DC40DC40-1240121.004.0460 L/H12.0
DC40DC40-1250121.205.0520 L/H14.4
DC40DC40-1860181.206.0600 L/H21.6
DC40DC40-2430240.353.0400 L/H8.40
DC40DC40-2440240.504.0460 L/H12.0
DC40DC40-2450240.555.0520 L/H14.4
DC40DC40-2460240.806.0600 L/H19.2
DC40DC40-2470241.007.0660 L/H24.0
DC40EDC40E-1250121.105.0500 L/H13.2
DC40EDC40E-2470241.107.0620 L/H26.4
DC40MDC40M-1215120.251.5350 L/H3
DC40MDC40M-1225120.402.5410 L/H5
DC40MDC40M-1230120.603.0480 L/H7
DC40MDC40M-1240120.753.5530 L/H9
DC45DC45A---850 L/H(flow range 500 / 700 / 750 L/H)-
DC45DC45D---1350 L/H(flow range 900 / 1200 L/H)-
DC50DDC50D-1260S124.0635 L/min48
DC50DDC50D-2480S243.608.045 L/min86.4
DC50HDC50H-12150S / 12150A124.515500 L/H52
DC50HDC50H-24200A / 24200S243.320600 L/H83
DC50KDC50K-1260T122.06.0900 L/H24
DC50KDC50K-12120S / 12120A124.5121260 L/H54
DC50KDC50K-2490T242.09.01080 L/H48
DC50KDC50K-24160S / 24160A243.60161380 L/H86.4
DC50MDC50M-1290S / 1290A124.391200 L/H52
DC50MDC50M-2480S / 2480A243.681150 L/H55
DC50MDC50M-24120S / 24120A243.3131350 L/H74
DC55DC55B---2400 L/H(flow 2000 L/H)-
DC55DC55E---2400 L/H(flow 2000 L/H)-
DC60DDC60D-12100S / 12100A126.7103000 L/H80
DC60DDC60D-24120S / 24120A244123300 L/H100
DC60GDC60G-12100 (PWM/VR/S)125.4 (6.6)103200 L/H65 (80)
DC60GDC60G-24120 (PWM/VR/S)244.5 (5)123800 L/H108 (120)
DC60GDC60G-36120 (PWM/VR/S)363 (3.3)123800 L/H108 (120)
DC65DC65A-12130PWM12-131700 L/H-
DC65DC65A-24250PWM24-252000 L/H-
DC80DDC80D-1265S1255.55300 L/H80
DC80DDC80D-2480S246.58.56300 L/H120
DC80EDC80E-1212--6500 L/H-
DC80EDC80E-2424--7000 L/H-
DC80EDC80E-3636--8000 L/H-


Selection Notes : 

1 . Listed current is the open-flow current.After connecting to a system, working current drops to about 70–85% of the max load current.

2 . Max head is the maximum water delivery height; flow is zero at max head.Flow is horizontal pumping flow unless otherwise noted.

3 . Pumps above 24W are not recommended for continuous operation above 60°C water temperature. Before selection, confirm continuous working time, water temperature, and medium.

4 . Many models are available with PWM, 0–5V analog signal, or potentiometer speed control.

5 . Optional protections: dry-run protection, no-load protection, locked-rotor protection, and stall protection.